Skip to main content
Advancing the quality of patient care

STERRAD® 100NX ALLClear™ Technology has the ability to minimize workflow interruptions before they occur. It is the only sterilization platform with integrated quality control features, which may enhance compliance*. Its unique features include:

  • Reduce workflow interruptions
    • Automatic pre-cycle detects and removes moisture before start of the sterilization cycle
  • Enhance compliance by greater adherence to device IFUs and improved record handling.
    • Automatic communication of information between the STERRAD® System, ASP ACCESS™ Technology, and Instrument Tracking System or Hospital Network
    • Fully compatible with the Independent Monitoring System (IMS) with sensors that allows for parametric release of instrument loads
  • Designed with simplicity in mind to reduce the potential for human error
    • Enhanced user interface makes cycle navigation intuitive and straightforward
    • Graphic display indicating proper load placement for the selected cycle
    • Automated cassette insertion mechanism
  • Upgradable and expandable sterilization system
  • Trusted and proven worldwide sterility
  • Increased healthcare worker safety**
  • Reduced costs for instrument repairing; less water and energy consumption**

The STERRAD® 100NX ALLClear™ Technology supports all 4 cycle options below:

Always refer to the STERRAD® Sterility Guide (www.sterradsterilityguide.com) for the latest updates on instruments’ validations and cycle and systems’ compatibility or contact medical device manufacturer for the detailed processing information.

*STERRAD® Systems with ALLClear™ Technology have features that may enhance compliance, such as on-screen reinforcement of user training.
** Ask your ASP Representative to provide you with the Operational Cost Case Study of STERRAD® Systems vs Steam Sterilizers.

  • Reduced workflow interruptions
  • Enhanced compliance by greater adherence to device IFUs and improved record handling.
  • Designed with simplicity in mind to reduce the potential for human error
  • Upgradable and expandable sterilization system
  • Trusted and proven worldwide sterility
  • Increased healthcare worker safety
  • Reduced costs for instrument repairing; less water and energy consumption
  • Fully compatible with the Independent Monitoring Systems (IMS) for parametric release

STERRAD® 100NX ALLClear System Specifications

Cycle Specifications*
Cycles Standard: sterilizes most general surgical instruments
Flex: sterilizes up to 2 single-channel flexible endoscopes
Express: sterilizes da Vinci® 3-D endoscopes and other delicate instruments without lumens
Duo: sterilizes cameras and up to 2 single-channel flexible endoscopes
Time Standard: 47 minutes Flex: 42 minutes Express: 24 minutes Duo: 60 minutes
Lumen claims Standard: diameter: ≥0.7 mm; length: ≤500 mm
Flex: diameter: ≥1 mm; length: ≤850 mm Express: nonlumen sterilization only
Duo: diameter: ≥1 mm; length: ≤875 mm
Technical Specifications
Cycle temperature 47°C-56°C
Sterilant Hydrogen peroxide
Sterilant delivery Delivered in closed system in cassettes with automatic detection of expiration date:
Standard/Express/Flex: 10.8 mL per cycle (double kill) (2 ampules, each ampule is 5.4 mL)
Duo: 3.1 mL per cycle
Used cassette disposal Automatic and touchless ejection into cassette disposal container
Peroxide residual breakdown Gas plasma technology breaks down H2O2 to safe elements of water and oxygen
Configurations Single and double doors
System dimensions (maximum) Height: 1800 mm Width: 775 mm
Depth: single door: 1055 mm; double door: 1095 mm
Chamber total volume 152 L
Chamber dimensions Height: 410 mm Width: 510 mm Depth: 735 mm
Chamber shape Rectangular
Shelf info Two-tiered shelf: Width: 444 mm Depth: 643 mm
Mobility 4 casters (2 locking)
System weight 1 door: 382 kg 2 door: 408 kg
User interface Touchscreen technology: projected capacitive touch Resolution: 800 x 600 pixels
Supported USB devices • Barcode reader • External drives: USB that allows data upload and download
• External printer connection (PCL3 compatible or equivalent)
Standards/Compliance ISO 14937
Sterilization Specifications
Sterilization process Terminal-sterilization, double-kill cycle to provide a Sterility Assurance Level (SAL) of 10-6; 2 injections and identical plasma phases
Delivered sterilant concentration 58%-59.6%
Sterilization cycle monitoring Critical system parameters monitored with on-board sensors, biological indicators, and chemical indicators; IMS (independent monitoring system) available
H2O2 concentration continuous monitoring Monitoring using UV sensor within the chamber
Installation and Electrical Requirements
Heat generation Idle: 4574 BTU/hour Maximum: 6187 BTU/hour
Electrical power specifications • US/Canada: 208 VAC, 60 Hz, NEMA L21-30 5-wire grounding twist-lock outlet attached to a dedicated 30-amp, 3-phase wye configuration circuit with separate neutral and ground conductors
• International: 380-415 VAC, 50/60 Hz, 5-wire grounding outlet attached to a dedicated 30-amp, 3-phase wye configuration circuit with separate neutral and ground conductors
• Japan: 200 VAC, 50/60 Hz: 4-wire grounding outlet attached to a dedicated 30-amp, 3-phase delta configuration with separate ground conductors
Installation space requirements In operation, the STERRAD® 100NX System with ALLClear™ Technology should not be placed closer than 50.8 mm from the rear wall. The power receptacle should be positioned 30.5 to 61 cm above the floor. For recessed systems, a clearance of 25 mm from the top of the system and 45 mm on each side of the system is required.
Service space requirements Service access requires a minimum clearance of 610 mm above the top and approximately 991 mm in on all sides of the system (can be less if the system can be moved for servicing).
Operational Environment
Temperature 18°C-35°C
Humidity 10%-85% RH (noncondensing)
Networking and Data Recording
System performance data and reports Cycle history, full 1-second data files, and reports available via ASP ACCESS™ Technology
Network connectivity Communication protocol for Instrument Tracking Systems (ITS) available via ASP ACCESS™ Technology
Data recording • Electronic data storage up to 200 cycles • Internal printer for manual recordkeeping
• Full electronic cycle data and reports via ASP ACCESS™ Technology
System Ordering Information
Code Product Description
10104-005 STERRAD® 100NX Sterilization System with ALLClear™ Technology, single-door unit, STANDARD & FLEX cycles, includes installation
10104-006 STERRAD® 100NX Sterilization System with ALLClear™ Technology, double-door unit, STANDARD & FLEX cycles, includes installation
10104-007 STERRAD® 100NX Sterilization System with ALLClear™ Technology, single-door unit, STANDARD, FLEX and DUO cycles, includes installation
10104-008 STERRAD® 100NX Sterilization System with ALLClear™ Technology, double-door unit, STANDARD, FLEX and DUO cycles, includes installation
10144 STERRAD® 100NX System Cassette (2 cassettes/case)
20227 Cassette Disposal Box (10 boxes/case)
10135 STERRAD® 100NX System EXPRESS Cycle Kit
10137 STERRAD® 100NX System DUO Cycle Kit
10305 Thermal Printer Paper (12 rolls/case)
113617-01 STERRAD® Systems Bar Code Scanner Kit

*Always refer to the STERRAD® Sterility Guide (www.sterradsterilityguide.com) for the latest updates on instruments’ validations and cycles and systems’ compatibility.